Heat Pumps Explained: Why SCOP, Not SEER, Should Drive Your Next Split Purchase

Most homeowners buy an air conditioner thinking about summer, then discover in December that the same split is quietly heating the house at a fraction of the cost of an electric radiator. The catch is that this only works if the unit is chosen correctly — and the number that matters for heating is not the cooling rating everyone stares at, but the SCOP, the seasonal coefficient of performance that European regulation translates into letter classes running from A+++ (SCOP of 5.10 or higher) down to G (below 1.90). Units placed on the market since 2019 display only A+++ to D on the label, which makes the fine print more important than ever.

  • SCOP beats raw power: The seasonal figure weighs performance across outdoor temperatures and partial loads, which is how an inverter actually runs in a real home.
  • Read both scales: The label carries SEER in blue for cooling and SCOP in red for heating, each with its own letter — and the mandatory class is the “average” season.
  • Subsidy mismatch: The heat-pump incentive scheme built on energy savings certificates targets hydronic systems replacing fossil-fuel boilers, not the air-to-air split most households already own.

What SCOP measures and why it outranks nominal capacity

SCOP is the heat delivered over an entire heating season divided by the electricity consumed over that same period. That definition comes from Delegated Regulation (EU) 626/2011, which governs energy labelling for air conditioners up to 12 kW — in practice, almost any domestic split. The key word is “seasonal.” The classic COP measures efficiency under fixed test conditions; SCOP weights how the equipment behaves at different outdoor temperatures and at partial load, which is how an inverter really operates. The regulation itself justifies the shift on the grounds that these devices run mostly at partial load and that the seasonal method better captures the advantages of inverter technology.

For reference, the regulation defines the backup electric heater that kicks in when the split cannot cope as having a COP of 1: one kWh of electricity for one kWh of heat. A split rated at SCOP 4 delivers roughly four times more heat per kWh under the reference-season conditions. That is the yardstick for comparing what each type of electric heating actually consumes, and it explains why the heat pump wins by a wide margin.

How to decode a reversible air conditioner’s label

The label shows two scales: SEER for cooling in blue and SCOP for heating in red, each with its own letter. For heating, the “average” season class is mandatory; the “warmer” and “colder” season classes are optional and appear as an X when not declared. The SCOP thresholds set by the regulation for splits are as follows: A+++ at 5.10 or above, A++ from 4.60 to 5.09, A+ from 4.00 to 4.59, A from 3.40 to 3.99, B from 3.10 to 3.39, C from 2.80 to 3.09 and D from 2.50 to 2.79.

The three seasons are not decoration. Annex VII of the regulation defines them with distinct design outdoor temperatures: −10 °C for the average season, +2 °C for the warmer one and −22 °C for the colder one. It also sets an operating limit temperature below which the unit stops heating: at most −7 °C in the average season and −15 °C in the colder one. The practical advice follows directly: if you live in a mild-winter zone, look for a model that also declares the “warmer” season, because it best matches your usage. If you live inland with hard frosts, the useful figure is the “colder” season — and a manufacturer that declines to declare it has already told you something.

Is the 2011 regulation still in force, and does the split qualify for subsidies?

Yes, it remains in force. The EUR-Lex record for Regulation 626/2011 lists it as a valid norm with no end-of-validity date and a last consolidated version of 30 September 2023 after several amendments. Spain’s IDAE also keeps it as the labelling regulation applicable to air conditioners and fans. A revision exists but is moving slowly: according to Eurovent, the association representing the European climate-control industry, the Commission presented drafts to revise ecodesign and labelling together at a consultative forum held on 7 March 2023, and the process remains open. Until a new regulation is published, the scale with the “pluses” and the table above are what you will see in stores.

A fair criticism: a letter scale with up to three pluses communicates worse than a number. The letter helps you discard options; to decide, look at the SCOP figure, which the label also prints to one decimal place.

It clearly pays off against any resistive electric heating and is the option the IDAE recommends when equipment is due for replacement; against a boiler, it depends on the type of heat pump and on available aid. In its household recommendations, the IDAE advises replacing heating and hot water with heat-pump systems at renovation time and choosing a heat-pump unit of class A or higher if you need both cooling and heating. It also reminds consumers that each extra degree on the thermostat means roughly 7% more climate-control consumption and that 21 °C is sufficient.

What you should know before doing the maths on subsidies: the heat-pump stimulus scheme built on Energy Savings Certificates (CAE), which the MITECO specified on 7 November 2026, is aimed at replacing fossil-fuel boilers with hydronic heat pumps — the kind that heat water for radiators or underfloor heating. Multipliers range from ×2 for a detached home to ×4 when a building moves from individual boilers to a centralised system, with an additional ×1.5 for vulnerable consumers, for actions initiated from 22 March 2026. An air-to-air split is not a hydronic heat pump, so it does not fall under that scheme.

That leaves two scenarios. If you have electric radiators or fan heaters, a reversible split with a strong SCOP is the most direct upgrade available, and sensible thermostat programming multiplies the effect. If you have a gas boiler feeding radiators, the honest comparison is not against the split but against an air-to-water system that reuses your water installation — precisely what the CAE scheme now incentivises.

The bottom line: an air conditioner with a heat pump is an excellent heating system that is badly sold, because it is bought with summer in mind and chosen by looking at the cooling letter. If your unit will heat the house four months a year, choose by the SCOP of your season rather than the SEER, and be wary of any datasheet that declares only the average season when you live in a climate that does not resemble it.